Probe

The Probe option helps to query and display CAE result values for specific nodes or elements as labels in the VCollab viewer.

image1

There are several kinds of Probes:

  • Current Result - Derived :

    Displays value of current derived result at probed ID. Shortcut:enable Probe and click on the model.

  • Current Result - Full :

    Displays base components of selected result. Shortcut:enable Probe and hit Alt + click on the model. X,Y,Z components for vector results like velocity or displacement.

    image2

    Translational and Rotational x,y,z for six degrees of freedom result.

    image3

    xx, yy, zz, xy, yz, xz components for tensor results like Stress in a matrix form.

    image4

  • All Results - Table :

    Displays all result values of the probed ID.

  • All Instances - Table :

    Displays all instance values of current result for the probed ID. Shortcut - enable Probe and hit Ctrl + left click.

  • All Instances - XYPlot :

    Displays XYPlot curve which describes instances vs CAE result values.

    Shortcut - enable Probe and hit Shift + left click.

  • Tracer: Displays path of a node traced in transient animation.

Steps to probe CAE results

  • Click CAE | Probe , which enables mouse mode to probe, Or

    Go to Probe icon image5 in the toolbar and click the down arrow next to the probe icon.

    A list of probe types is shown.

    image6

  • Select a Probe type.

  • Click on a node to probe its current CAE result.

  • Notice that the CAE value with nodal number is displayed as a label in the viewer.

  • Click Probe Settings and open the Label Settings dialog box.

    image7

  • Select the required tab and apply the settings to particular portions of the probe label.

    Current Result - Derived

    image8

    Current Result - Full

    image9

    All Results - Table

    image10

    All Instances-Table

    image11

    All Instances - XYPlot

    image12

    Tracer

    image13

Probe Table Details

The probe table details are split into three regions.

  1. Header : This corresponds to the table header. It contains node or element ID. In case of merging more than one model, this header contains more than one ID and each ID refers to one column in the value region.

  2. Row Header: The row header holds the model name for the column data. It is useful when comparing multiple models.

  3. Column Header: The column header lists all the result names. It contains only abbreviations of results. For e.g., D is for displacement. Users can refer to the abbreviation table if necessary.

  4. Value Region: These cells hold the values corresponding to column and row header.

    image14

Probe Label Context Menu

To open the context menu, double click on a label.

image15

The various options available under the Probe label context menu are explained below.

Edit Font

Change the font and its attributes.

Display

Show/hide the selected label headers and label legends.

Modify

Modify or edit the table except existing result values. It is visible for Model header, Result header and Value cells. It is not applicable for ID header and Part header cells.

Mark Min & Max

Highlight the table if value is maximum or minimum among the available tables.

Focus Node

Focus the nodal vertex region based on levels.

Hide Label

Hide the selected label.

Delete Label

Delete the selected label.

Show All Labels

Shows all labels independent of attached position visibility

Hide All Labels

Hide all labels.

Delete All Labels

Delete all existing labels.

Delete All Hidden Labels

Delete all hidden labels.

Invert Show Labels

Invert the labels’ visibility.

Fit Labels

Fit all labels inside the viewer.

Autofit Labels

Fit all labels inside the viewer during scene rotation, zoom and pan.

Arrange Labels

Arrange all labels and tables in multiple rows according to their attached positions in the model.

Auto Arrange Labels

Arrange all labels automatically whenever the user modifies the label or table dimensions

Set As Default

Sets the probe table format settings and probe type as default In case of viewpoint, these settings will be overridden by viewpoint label settings. (i.e., viewpoint label format will be set as default)

Display Submenu

image16

ID

Show or hide table header.

Part

Show or hide part name header

Row Header

Show or hide row header.

Column Header

Show or hide column header.

Rank

Show or hide Rank cell.

Ascending Rank

Rank will be displayed in ascending or descending order.

Abbreviations

Show or hide result abbreviations table.

Transpose

Transpose the table matrix.

Highlight

Highlight the picked label.

Modify Submenu

The Modify submenu is different depending on the type of the label cell double clicked. If the clicked cell is a value cell, then Field Value… and Precision… appear. Header Name… appears for model and result header cells.

Value Cell

image17

Model/Result Header Cell

image18

Field Value

Edit values and update it to multiple cells across all viewpoints.

Precision

Change precision and formats.

Add Row

Add a new row at the end.

Insert Row

Insert a new row at the mouse cursor position.

Add Column

Add a new column at the end.

Insert Column

Insert a new column at the mouse cursor position.

Delete Row

Delete the specified row.

Delete Column

Delete the specified column.

Header Name

Edit the header display name.

Delete Row Current

Delete current cell row (based on the cursor position).

Delete Column Current

Delete the current column.

Focus Node Submenu

Double click on a label cell to open the context menu. Click on focus node option

image19

Focus Node helps to zoom in the nodal vertex region in four levels for better visualization:

  • Level 0 focuses on the element associated with the nodal vertex.

  • Level 1 focuses on the nodal vertex with 1/10th of part bounding radius.

  • Level 2 focuses on the nodal vertex with 1/4th of part bounding radius.

  • Level 3 focuses on the nodal vertex with part bounding radius.

Steps to scale Geometry or Parts before Probing

  • Click Edit | Product Explorer, which displays the product tree.

  • Click the group node, not leaf node.

  • Right click on the node to open the context menu.

  • Select Transform option.

  • Check the Scale option.

  • Enter the scale factors for each coordinate axis. The model is scaled and is ready for probing.

Steps to Edit and format Table

  • Double click on the table header cells to open the context menu

  • Click Modify | Header Name to change the header or result name.

    image20

  • Check Update Viewpoints option to update all viewpoint tables.

  • Enter a name and click OK to update the table.

  • Right click on a value cell and select Edit Font to open the Edit Font Dialog panel.

    image21

    Apply to Tables

    Set either current table or all tables

    Apply to Fields

    Set all fields or current field or current column.

    Font

    Change the font

    Font Size

    Change the font size.

    Text Color

    Change text color

    Background Color

    Enable/disable background and select a color.

    Align

    Align the label text into left, right or center horizontally.

    Scientific & Precision

    Allows user to modify the numberic format

    Update All ViewPoints

    Apply and update the modifications to viewpoints too.

    Update Merged Models

    Update all merged model probe labels. This option will be visibile only in merged models case.

  • Make necessary changes and click OK.

  • Double Click on the value cell to open the context menu and edit the value.

  • Click ‘Modify | Field Value…’ option which opens the Edit Table Value panel. This is only applicable for user added cells.

    image22

  • Edit the value and update the modified value to all update viewpoints if needed

  • Select All Tables and All Fields options to apply the modifications to all viewpoints.

  • The modified value can be applied to all fields or the column selected or current cell or field.

  • Click OK to apply all modifications.